Aquaterra Energy has secured a major contract for a High Pressure Marine Riser System from Apache North Sea Limited.
SERVICES
Riser Analysis
Requirements
- Optimise Conductor and Casing Sizes.
- Increase Operational Window.
- Follow ‘Current Best Industry Practice’ as stated by the HSE.
- Avoid Damage or Loss of Equipment.
- Minimise Possible Environmental Damage.
-
Accurate Centraliser Requirements.
The Solution
A comprehensive analysis tailored to the requirements and the most appropriate regulations. Each analysis has a model built specifically for the problem and the results are displayed in clear graphical and tabulated formats within a concluding report.
The HSE states that: It is the well operator's duty to ensure the subject equipment is suitable, and that the Executive may request a demonstration of suitability of such equipment and Riser Analysis is considered 'current best industry practice.'
Aquaterra Energy utilises multiple recognised programs to ensure accurate results for both deep and shallow water studies.
Features & Benefits
- Strength and Stability Analysis
- Pile/Soil Modelling
- Fatigue Life
- Vortex Induced Vibration (VIV) Analysis
- Snag Loading
- Thermal Analysis
- Pipe in Pipe (Clashing/Gap Element Analysis)
- Wear Analysis
- Vessel Motion
- Integrated Riser, LMRP, BOP, Wellhead, Conductor Analysis
- Impact Loading Analysis